Commercial Insulation and Fireproofing

Since 1979, Payless Insulation has specified and installed commercial insulation and fireproofing in Houston and Austin buildings, whether empty or fully occupied.  Its four commercial systems are spray-applied fireproofing, thermal insulation, acoustic insulation, and insulation removal.

Commercial Insulation and Fireproofing installed by Payless Insulation in Houston and Austin

Payless Insulation has installed commercial insulation and fireproofing in Houston and Austin since 1979. Its crews work in empty or fully occupied buildings, from a single shipping container to one million square feet, and handle every job from trim-out to cleanup. The four commercial systems are spray-applied fireproofing, thermal insulation, acoustic insulation, and insulation removal, offered from offices in both cities.

Request a free commercial insulation quote or call the nearest office: Houston (713) 868-1021, Austin (512) 339-1021.

Commercial insulation services cover four systems in a Texas building

Payless Insulation installs four commercial systems, and each one is measured by a different rating. Fireproofing is rated in hours, thermal insulation in assembly U-factor and R-value, acoustic work in STC and NRC, and removal by the containment and disposal method. The assessment identifies which metrics the project must meet before the quote is written. A build-up, or assembly, is the full layered stack of materials that makes up a wall, floor, roof, or ceiling, and a rating belongs to that whole stack rather than to any one material in it.

Fireproofing installation

Spray-applied Fireproofing

Spray-applied fireproofing protects a building's steel frame so the structure holds up long enough for people to get out, which is what the hourly fire rating measures. In a fire, unprotected structural steel softens and can buckle, and the fireproofing buys time. Payless Insulation applies three system types. Spray-applied fire-resistive material (SFRM) is the spray-on coating used on most structural steel. Cementitious fireproofing is a denser, more durable version for areas that call for it. Intumescent coatings are a paint-like finish for steel that stays visible in the finished space and has to look good. The hourly rating comes from a tested assembly, and the crew applies each coating at the thickness that assembly's listing calls for. Products applied include Cafco, Monokote, and Carboline.

Commercial Thermal Insulation

Commercial thermal insulation lowers energy cost, extends HVAC life, and stops condensation on metal building skins. Payless Insulation installs closed-cell spray foam where the assembly needs an air barrier and vapor retarder in one product, spray-applied K-13 cellulose on exposed decks and ceilings, and blown or batt insulation in framed cavities. Commercial code sets its minimums as assembly U-factors, a rating for the whole wall or roof, on top of the R-value of the insulation itself. A continuous layer of insulation that runs across the framing, not just in the gaps between it, stops heat from taking a shortcut straight through the steel or studs. The code calls that shortcut thermal bridging.

Fireproofing installation

Acoustic and Sound Reduction Insulation

Acoustic insulation solves two different problems, and the product depends on which one the building has. Sound transmission through a wall or floor is rated by Sound Transmission Class (STC), and reflected sound inside a room is rated by Noise Reduction Coefficient (NRC). Payless Insulation applies K-13, SonaSpray, and SonaKrete finishes for absorption in restaurants, auditoriums, sound stages, machine shops, convention halls, and parking garages. To raise STC between rooms and units, it fills wall and floor-ceiling cavities with Celbar wet-spray cellulose.

Commercial Insulation Removal

Commercial insulation removal is scheduled around occupancy, contained at the work area, and disposed of by the crew. Wet, contaminated, or settled material comes out before a new system goes in, and the same crew reinstalls the replacement.

Commercial envelope work in Houston and Austin follows the 2021 IECC or ASHRAE 90.1

Commercial buildings in Houston and Austin have to meet one of two energy codes: the 2021 International Energy Conservation Code, or ASHRAE 90.1 if the project uses that standard instead. The building shell, or envelope, is the outer boundary that separates the heated and cooled inside of a building from the outdoors, meaning the exterior walls, the roof, and the foundation floor. Both cities enforce the 2021 edition, two editions ahead of the Texas state baseline of 2015. ASHRAE 90.1 is the energy standard for buildings other than low-rise residential and applies to commercial work and to residential above three stories when it is chosen as the compliance path. Which energy code applies to your project and when ASHRAE 90.1 governs instead set out the decision.

Here is the practical difference for the insulation scope. On a house, the code usually sets one R-value for the insulation. On a commercial building, the code grades the whole wall or roof as a single unit, using a figure called the assembly U-factor, so the insulation, the framing, and the sheathing all count toward the score together. A second route, called the performance path, lets a building make up for a weaker spot in one place with a stronger one somewhere else, as long as the whole building still hits its energy target. Payless Insulation reads which route the drawings use and specifies the build-up to match.

Mid-rise and multifamily assemblies carry both a fire rating and an STC requirement

In a mid-rise or multifamily building, the wall between two units has to do two jobs at once: hold back a fire for a set number of hours and block sound from passing between the units. The International Building Code requires both. The fire job is the fire rating, and the sound job is measured as a minimum Sound Transmission Class (STC). That makes multifamily the one building type where fireproofing, thermal, and acoustic work all meet in a single assembly. In Texas the rules also change above three stories, where taller residential buildings start to follow the commercial code.

Payless Insulation installs the insulation inside the shared walls between units, the floor-and-ceiling layers that separate one story from the next, and the fireproofing on the building’s structural frame, for mid-rise and multifamily projects in both metros. What separates multifamily units for fire and what STC multifamily party walls require carry the assembly detail. View mid-rise projects and commercial projects.

Which commercial insulation system does a building need?

The building type sets the problem, and the problem sets the system. Seven common cases:

Building TypeProblemSystemRating or Code to Meet
Metal buildingCondensation on the skin, heat gainClosed-cell spray foam, K-13, or spray-on vinylAssembly U-factor, vapor permeance
Office or InstitutionalEnvelope compliance, HVAC loadCavity and continuous insulation2021 IECC or ASHRAE 90.1
Restaurant or VenueReflected noiseK-13, SonaSpray, SonaKreteNRC (set by finish thickness)
Machine shop or PlantNoise exposure, heatSpray-applied acoustic finish, spray foam, and fireproofingNRC, occupational noise limits, fire rating
Parking GarageReflected noise, exposed structureK-13 on deck, spray foam, and fireproofingNRC, fire classification
Multifamily or Mid-RiseUnit separationParty wall cavity insulation plus structural fireproofingIBC fire rating and STC
Structural Steel, any typeHourly ratingSFRM, cementitious, or intumescentHourly fire rating of the tested assembly

Payless Insulation installs to the listed assembly and documents the result

A fire rating applies only when the field installation matches the tested assembly it was listed under. The assembly, again, is the whole layered build-up, here the structural steel plus its fireproofing at the listed thickness. Payless Insulation applies fireproofing to the thickness and density the listing specifies, records it, and makes the record available to the inspector. Thermal and acoustic work is installed to the assembly on the drawings for the same reason: the rating belongs to the assembly, not to the material.

The company is bonded and insured and has held an A+ Better Business Bureau rating since 1980. For public and institutional procurement it holds Texas HUB certification and City of Houston Woman Business Enterprise, Disadvantaged Business Enterprise, and Small Business Enterprise certifications. It is a member of the Greater Houston Builders Association, the U.S. Green Building Council, and the National Association of Home Builders. The full list is on certifications and awards.

Request an Insulation Quote in Houston or Austin Texas

Payless Insulation helps you choose the right insulation for your home or commercial building and your budget. Every free estimate includes a written recommendation before any work starts.

This field is for validation purposes and should be left unchanged.
Name(Required)
Project Address(Required)

Answers to common questions about commercial insulation in Texas

Which energy code applies to a commercial building in Houston or Austin?

Both cities enforce the 2021 IECC, and a commercial project can use ASHRAE 90.1 instead. The drawings say which one applies, and Payless Insulation designs the envelope assembly to match it. The envelope, again, is the building’s outer shell of exterior walls and roof.

How is the hourly fire rating on structural steel established?

The hourly rating comes from a tested assembly listing, and the applied thickness has to match that listing. Payless Insulation applies SFRM, cementitious, or intumescent systems to the listed thickness and density and records the result for inspection.

What is the difference between STC and NRC?

STC rates how much sound an assembly stops from passing through it, and NRC rates how much sound a surface absorbs instead of reflecting. A party wall between apartments is an STC problem, a loud restaurant dining room is an NRC problem, and the two call for different products.

Can the work be done while the building is occupied?

Yes. Payless Insulation schedules and contains commercial work in occupied buildings, from a single suite to a fully tenanted structure. The crew sets the containment, works the agreed hours, and cleans the area at the end of each shift.

Does Payless Insulation work outside Houston and Austin?

Payless Insulation runs commercial crews from Houston and Austin and works throughout the areas around both cities. For a project outside that range, ask when you request a quote and Payless Insulation will confirm whether it is serviceable.

Request a commercial insulation quote in Houston or Austin

Payless Insulation quotes commercial work from two offices. Houston: (713) 868-1021, 1830 W. 15th St., Houston, TX 77008. Austin: (512) 339-1021, 2200 Denton Dr., Suite 111, Austin, TX 78758. Office hours are Monday through Friday, 8 AM to 5 PM, with emergency service available 24/7.

Request a commercial insulation quote